Skip to content

Hoshizaki KMD-355MWJ water-cooled modular crescent-cube ice maker with up to 395 lb/day production at 70°F air and 50°F water. Stainless steel exterior and adjustable ultrasonic bin sensing. Head only; compatible storage assembly and top kit sold separately. Independent condenser-water circuit required.

In Stock
Shipping calculated at checkout.

Product overview

The Hoshizaki KMD-355MWJ is a water-cooled modular crescent-cube ice maker producing up to 395 lb per 24 hours at 70°F air and 50°F water. At 90°F air and 70°F water, production is 385 lb per 24 hours. This product supplies one ice-making head; a compatible dispenser or storage bin and the required top kit are selected separately.

The stainless steel exterior and individual crescent cubes suit a separately configured ice-storage or dispensing installation. Factory-installed ultrasonic bin sensing allows the shutoff level to be set for the selected storage assembly. CleanAssist supports the cleaning sequence, followed by the separate sanitizing and rinse procedure.

  • Up to 395 lb/day: Rated at 70°F air / 50°F water.
  • Water-cooled system: Independent condenser-water circuit required.
  • Modular head only: Dispenser or storage bin and top kit sold separately.

Specifications

Model KMD-355MWJ
Ice form Individual crescent cubes
Condenser Water-cooled
Ice production at 70°F air / 50°F water Up to 395 lb per 24 hours
Ice production at 90°F air / 70°F water 385 lb per 24 hours
Integrated ice storage None; separate storage assembly required
Exterior Stainless steel
Bin control Adjustable ultrasonic sensor
Electrical supply 115V / 60Hz / single phase
Rated amperage 7.4 A
Minimum circuit ampacity 15 A
Maximum fuse / HACR breaker 15 A
Power connection Hardwired; no cord or plug included
Refrigerant R-404A
Potable-water inlet ½-inch FPT
Head drain outlet ¾-inch FPT
Inlet-water temperature 45–90°F
Potable-water pressure 10–113 PSIG
Potable-water use at 90°F air / 70°F water 34.5 US gal per 100 lb of ice
Energy use at 90°F air / 70°F water 4.40 kWh per 100 lb of ice
Operating ambient 45–100°F
Condenser-water use at 90°F air / 70°F water 155 US gal per 100 lb of ice, additional to potable water
Condenser-water inlet ½-inch FPT
Condenser-water outlet ⅜-inch FPT

Daily production is not storage capacity. Output and utility use vary with air and water temperatures, water quality and installation. Confirm the complete head, top kit and storage-assembly envelope, utility projections and service access before final fit-out.

Dispenser or bin selection

Match the exact head, top kit, ice-drop opening, bin-control position and mounting pattern to the selected dispenser or bin. A nominal width match alone does not establish compatibility. Secure both assemblies and test the bin control during commissioning. Keep the ice path and control movement or sensing area clear.

Use a storage assembly at least 30 inches wide. The B-500 and BD-500 series are recommended bin ranges. The bin/dispenser and any required top kit are sold separately; verify the exact mounting arrangement before ordering.

Set the ultrasonic sensor for the actual bin or dispenser application. A storage-bin setting is not automatically correct for a dispenser. Keep the lens and required openings unobstructed and confirm that the selected shutoff level prevents overflow, leakage or movement of the head.

Installation and electrical supply

Install the head indoors on a firm, level support away from ovens, grills and other high-heat equipment. Leave at least 6 inches at the rear, both sides and top. Allow space to remove panels and move utility lines for service. Operate the head in a 45–100°F room. Drain and winterize the machine and water lines before freezing exposure or extended non-use.

Have a qualified electrician provide an independent, grounded 115V / 60Hz / single-phase hardwired supply with 15 A minimum circuit ampacity and 15 A maximum fuse/HACR protection. Connect line, neutral and ground, with the white lead connected to neutral. The ⅞-inch supply opening accepts ½-inch trade-size conduit. Match the delivered nameplate and applicable codes. If GFCI protection is required, use a GFCI breaker rather than a receptacle.

Water supply and drainage

Supply potable water at 45–90°F and 10–113 PSIG through at least ¼-inch nominal-ID copper tubing or equivalent, with shutoff and drain valves. Correct water hammer and select water treatment for local conditions. Provide enough utility-line allowance for service movement.

Use at least ¾-inch nominal-ID hard pipe or equivalent for the head drain. Keep head and storage drains independent, with vented tees, a ¼-inch fall per horizontal foot and at least a 2-inch vertical air gap at each pipe end above an approved drain. Do not connect drains directly to the sewer.

Condenser-water circuit

Provide a separate condenser-water supply and drain or closed-loop return. Use at least ¼-inch nominal-ID copper tubing or equivalent for supply and closed return, or hard pipe for open drainage. Keep open condenser drainage independent of the head and storage drains. Include shutoff and drain valves at both ends of a closed-loop installation.

A closed loop requires at least 4 GPM, at least 10 PSIG inlet-to-return pressure differential and less than 30% glycol. Keep condenser inlet water at or above 45°F; have qualified personnel confirm a 104–115°F outlet temperature five minutes into the freeze cycle. Condenser-water consumption is additional to the potable water used to make ice. No remote condenser is required.

Cleaning and maintenance

Clean and thoroughly rinse the scoop daily. Each month, check external water filters and clean the exterior, underside of the head and top kit, and the storage door or snout. Clean and thoroughly rinse the ultrasonic bin-control lens monthly.

Clean and sanitize the head and storage assembly at least annually, with more frequent service when water quality or sanitation requirements demand it. Annual maintenance includes the inlet screen, hoses and condenser. CleanAssist cleaning must be followed by the separate sanitizing and rinse sequence.

Do not use ammonia-type cleaners. Have qualified service personnel isolate and lock out power before maintenance, follow the prescribed procedures and secure every component, fastener and thumbscrew afterward. Follow the complete draining and winterization instructions before extended non-use or freezing conditions.

Limited warranty

Limited coverage provides three years of machine parts and labor, five years of evaporator parts and labor, and five years of compressor parts for the original owner/user. Register within 30 days of installation and retain installation records. Standard coverage applies in the United States, Canada, Puerto Rico and U.S. territories. Travel, mileage and premium labor are excluded, as are damage from improper installation, utilities or maintenance. Review the written warranty for start-date rules and full terms.

Compare KMD crescent-cube heads

Choose the production rating, condenser type and exact mounting/control configuration for the planned storage assembly. Each head and accessory is sold separately. KMD-860MRJZ · KMD-860MWJ · KMD-505MRJZ · KMD-705MRJZ · KMD-410MWJ · KMD-355MWJ · KMD-505MWJ · KMD-410MAJ

Product documents