Skip to content

Hoshizaki PT1A-FS-FS one-section pass-through refrigerator with 24.2 cu. ft. capacity, 2 full-height stainless steel doors and access from both sides. Includes 3 adjustable main shelves, LED lighting, locks, 4-inch casters and a 115V cord-and-plug connection.

In Stock
Shipping calculated at checkout.

Product overview

The Hoshizaki PT1A-FS-FS Steelheart pass-through refrigerator provides 24.2 cu. ft. of refrigerated storage with access from both sides of the cabinet. Its one-section layout has 2 full-height stainless steel doors—1 on each side—so loading and retrieval can take place from opposite work areas.

Full-height doors provide access to the shelving across the cabinet’s full door opening. 3 adjustable epoxy-coated wire shelves support flexible storage, while interior LED lighting helps staff locate items. Stainless steel interior surfaces and exterior front, sides and top suit daily commercial use.

  • 24.2 cu. ft. AHAM capacity: One section with front and back access.
  • Full-height stainless steel doors: Standard locks and removable magnetic gaskets.
  • 115V plug-in connection: 5A rated current; NEMA 5-15P plug on a 10-foot cord.

Specifications

Model PT1A-FS-FS
Series Hoshizaki Steelheart
Configuration One-section pass-through refrigerator
Door configuration 2 full-height stainless steel doors; 1 per side
Interior capacity (AHAM) 24.2 cu. ft.
Overall dimensions (W × D × H) 27.5 × 35.75 × 79.5 inches; height includes standard 4-inch casters
Cabinet construction Stainless steel interior and exterior front, sides and top
Insulation 2⅜-inch CFC-free foamed-in-place polyurethane
Adjustable main shelves 3 epoxy-coated wire shelves; adjustable in 1-inch increments
Main shelf dimensions (W × D) 21.25 × 30.75 inches
Lighting Interior LED
Door locks Standard
Door gaskets Removable snap-in magnetic gaskets
Door operation Spring-assisted self-closing; stays open past 90°
Hinging Field reversible
Refrigeration Top-mounted, self-contained
Refrigerant R290; 4.6 oz (130 g)
Evaporator Epoxy electrocoated (E-Coat)
Refrigerant control Thermostatic expansion valve (TXV)
Controller Digital temperature display in °F or °C; temperature and voltage alarms
Control setpoint range 31–52°F; adjustment range, not a food-holding recommendation
Ambient operating range 45–100°F
Electrical supply 115V / 60Hz / single phase
Rated current 5A
HACR breaker 15A
Plug and cord NEMA 5-15P; 10-foot cord
Nominal compressor ¼ HP; 770 BTU/hr
Energy consumption (ASHRAE) 1.31 kWh/day
Mobility Standard 4-inch casters
Minimum room floor area 6.2 m² (67 sq. ft.)

Door access and storage

Flush-mounted aluminum handles keep the door profile compact. Heavy stainless steel hinge plates with welded hinge pins support the doors, and the stepped door design helps protect the recessed gaskets during loading.

Arrange shelving around the containers used in your operation. Keep internal air passages clear so the ducted airflow can circulate around stored products. The self-contained refrigeration system includes an accessible top condenser filter and hot-gas condensate evaporation.

Installation and electrical planning

Install indoors on a level, supporting floor and leave working room for door swing and loading on both sides. Keep ventilation and top filter/service access unobstructed. Minimum cabinet clearance is 0 inches at the sides and top; the rear clearance designation is not applicable to this pass-through layout.

Use a properly grounded, independent 115V outlet and the supplied three-prong plug; do not use an extension cord. Have a qualified installer verify the nameplate, circuit and local installation requirements. If GFCI protection is required, use a GFCI breaker rather than a GFCI receptacle.

R290 is a flammable refrigerant. Provide at least 6.2 m² (67 sq. ft.) of room floor area and do not install this unit in a public corridor or lobby. Follow the installation manual for placement and refrigerant safety requirements. Choose the operating setpoint for the food being stored, rather than treating the controller’s full adjustment range as suitable for every food.

Cleaning and maintenance

Move food to another refrigerator, switch the unit off and unplug it before cleaning. Clean the cabinet and removable door gaskets with suitable mild cleaning products; avoid damaging the stainless steel surfaces or refrigeration tubing. Inspect the air filter at least twice a month and wash it with warm water and neutral cleaner when dirty. Inspect the condenser twice a year; clean it at least annually and sooner as needed. Clean the condenser wick at least annually. Busier or dustier kitchens may need more frequent maintenance. Refrigeration service should be performed by qualified technicians.

Compare Steelheart pass-through refrigerators

Choose the cabinet width, door construction and access pattern that fit your workflow. These are separate models, not included companion units. Dimensions below include the standard casters.

Model Doors, capacity & dimensions
PT1A-FS-FS Full-height stainless steel; 24.2 cu. ft.; 27.5 × 35.75 × 79.5 inches
PT1A-HS-HS Half-height stainless steel; 24.2 cu. ft.; 27.5 × 35.75 × 79.5 inches
PT1A-FG-FG Full-height glass, anodized aluminum frame; 24.2 cu. ft.; 27.5 × 37.75 × 79.5 inches
PT2A-FS-FS Full-height stainless steel; 52.5 cu. ft.; 55 × 35.75 × 79.5 inches
PT2A-HS-HS Half-height stainless steel; 52.5 cu. ft.; 55 × 35.75 × 79.5 inches
PT2A-FG-FG Full-height glass, anodized aluminum frame; 52.5 cu. ft.; 55 × 37.75 × 79.5 inches
PT1A-FGE-FGE Full-height glass, stainless steel frame; 24.2 cu. ft.; 27.5 × 35.75 × 79.5 inches
PT2A-FGE-FGE Full-height glass, stainless steel frame; 52.5 cu. ft.; 55 × 35.75 × 79.5 inches